Latestproductsandinformationavailableatwww.sealite.com
12
AIS Monitoring System
with SLC600 Type 2 Power Supply
Trouble Shooting
Problem Remedy
Lanternwillnotactivate. • Ensurelanternisindarkness.
• Waitatleast60secondsfortheprogramtoinitialiseindarkness.
• Ensureswitchsettingisonavalidcode(notunusedashcode).
• Ensurebatteryterminalsareproperlyconnected.
• Ensurebatteryvoltageisabove12volts.
Timingcodeswillnotchange. • Turnrotaryswitchesseveraltimestoensurecontactsareclear.
Lanternwillnotoperateforthe
entire night.
• Exposelanterntodirectsunlightandmonitoroperationforseveraldays.
Sealiteproductstypicallyrequire1.5hoursofdirectsunlightperdayto
retainfullautonomy.Fromadischargedstate,thelanternmayrequire
severaldaysofoperationalconditionsto‘cycle’uptofullautonomy.
• Reducingthelightoutputintensityordutycycle(ashcode)willreduce
currentdrawonthebattery.
• Ensuresolarmoduleiscleanandnotcoveredbyshadingduringtheday.